Nebulae Solutions LTD.

Home › Laboratory testing

Laboratory testing

Independent, representative testing that answers a specific operating question. Here is how each test works, what it measures and how the results are used.

  • KHI and AA qualification
  • Hydrate equilibrium
  • Source gas systems
  • Wax
  • Scale
  • Corrosion
  • Compatibility
bar Hydrate, wax, scale and corrosion testing

Our approach to testing

Good laboratory work starts with the question, not the equipment. Before testing we agree what decision the results will support, for example "Can this KHI protect the flowline at the maximum shut-in subcooling for 48 hours?" or "Which of three scale inhibitors gives the lowest MIC in this brine?". The test matrix, fluids and acceptance criteria follow from that.

  • Independent: we are not a chemical supplier, so products are compared on equal terms.
  • Representative: gas, condensate and brine compositions, pressures, temperatures and water cuts that match the field.
  • Statistically sound: hydrate nucleation is random, so key tests use several cells and repeats rather than a single run.
  • Controlled: blanks (no chemical), reference chemicals and calibrated sensors in every programme.

Hydrate equilibrium measurement

The hydrate equilibrium (dissociation) point is measured with the isochoric step-heating method. A cell of fixed volume is loaded with water (or brine and inhibitor) and gas, cooled until hydrates form, then heated in small steps with long holds so the system reaches equilibrium at each step.

While hydrates form, gas is taken into the crystal and the pressure falls more than cooling alone would cause. On heating, hydrates dissociate and release gas. The point where the heating curve rejoins the cooling curve in the pressure–temperature plot is the equilibrium point at that pressure.

Cooling Hydrates form: extra pressure drop Step heating Dissociation (equilibrium) point Temperature Pressure
Isochoric test, schematic. The dissociation point measured at several pressures builds the equilibrium curve.

Repeating the test at several pressures builds the full curve for the field fluids, with and without inhibitors. These measurements validate or tune the thermodynamic model used for design. We check the method regularly against reference systems such as pure methane and water.

KHI testing and qualification

Kinetic hydrate inhibitors do not prevent hydrates thermodynamically; they delay them. Their performance is therefore described by how much subcooling they can handle and for how long. Two complementary test types are used:

Constant cooling (ramping)

The cell is cooled at a fixed rate until hydrates form. The onset temperature gives the subcooling the KHI tolerated. Useful for ranking products quickly.

Isothermal hold

The cell is taken to a fixed subcooling and held. The induction time before formation shows how long the KHI protects at field conditions. Used for qualification.

Tests run in rocking cells (several cells in parallel for statistics) and stirred autoclaves (better control of mixing and gas uptake). Formation is detected from pressure drop, temperature spikes from the heat of formation and, in rocking cells, from the steel ball slowing or stopping.

What decides a pass

  • Maximum subcooling the line will see, including shut-in and restart, plus a safety margin.
  • Required hold time: residence time in the cold section or the longest planned shut-in.
  • Behaviour after formation: slow, manageable growth versus catastrophic growth.
  • Effect of salts, condensate, pressure and any methanol or MEG used alongside the KHI.
  • Practical properties: cloud point (KHI polymers can come out of solution when heated, for example in a MEG regeneration reboiler), compatibility and viscosity at injection temperature.

Anti-agglomerant testing

Anti-agglomerants allow hydrates to form but keep the particles small and dispersed in the hydrocarbon phase. The question is therefore not "do hydrates form?" but "does the fluid keep flowing?".

  • Water cut sweep: AAs work up to a limiting water cut, which we find by testing a range.
  • Flow indicators: ball movement in rocking cells and stirrer torque in autoclaves show whether a slurry stays mobile.
  • Shut-in and restart: the critical case, where particles settle and must re-disperse when flow restarts.
  • Side effects: AAs are surfactants, so emulsion tendency, water quality and separation performance are checked too.

Source gas and fluid systems

Results are only as good as the fluids used. We build test fluids to match the field:

  • Synthetic natural gas blended from C1 to C4 hydrocarbons, CO2 and N2 to match the field gas composition, which controls hydrate structure and equilibrium.
  • Recombined fluids from separator gas and liquid samples where live fluid behaviour matters.
  • Synthetic brines made up from the formation water analysis, including the ions that drive scale and affect hydrate equilibrium.
  • Field condensate or crude where the hydrocarbon phase affects inhibitor partitioning or AA performance.

Wax testing

PropertyTypical methodsUsed for
Wax appearance temperature (WAT)Cross-polarised microscopy, differential scanning calorimetry, viscometryWhere wax risk starts
Pour pointASTM D97 and ASTM D5853 (crude oils)Gelling and restart risk
Gel strength / yield stressControlled-stress rheometry after coolingRestart pressure
Wax content and carbon number distributionPrecipitation methods, gas chromatographyDeposition modelling
Deposition rateCold finger, small flow loopPigging frequency, inhibitor selection

Wax inhibitors and pour point depressants are screened by their effect on WAT, pour point, gel strength and deposition, at the dose and injection temperature the field can use.

Scale testing

  • Compatibility tests: mixing formation and injection waters at field temperatures and ratios to see if and what precipitates.
  • Static bottle tests: inhibitor efficiency over time for sulfate and carbonate scales.
  • Dynamic tube blocking tests: scaling brine pumped through a narrow coil at temperature; the time to blockage with and without inhibitor gives the minimum inhibitor concentration (MIC).
  • MEG system tests: carbonate scaling under pH stabilisation and regeneration conditions.

Corrosion testing

  • Bubble cell tests with linear polarisation resistance (LPR) for fast corrosion inhibitor screening in CO2-saturated brine.
  • Rotating cylinder electrode tests to include the effect of wall shear stress.
  • High-pressure autoclave weight-loss tests at field CO2 and H2S partial pressures.
  • Combined chemistry tests to show whether hydrate inhibitors or scale inhibitors reduce corrosion inhibitor performance, or the reverse.

Chemical compatibility and product qualification

A chemical that performs well alone can cause problems in the full system. Qualification programmes therefore include:

  • Compatibility of each chemical with the others it will meet, and with the produced water.
  • Thermal stability and cloud point, including in MEG regeneration conditions.
  • Emulsion, foaming and water quality effects on separation.
  • Compatibility with elastomers, seals and umbilical materials.
  • Viscosity and stability at the injection temperature and pressure.

What you receive

  • A test plan agreed before work starts, with acceptance criteria.
  • A report that answers the original question first, then the data and method behind it.
  • Raw data on request, so results can be checked or reused.
  • A debrief with your engineers to turn the results into operating decisions.